MACF0801 Dual‑Lamp Laser Scanning Galvanometer
Overview
High‑precision marking solution with standard input spot diameter < 6.5 mm.
System Architecture
• Digital servo driver
• High‑resolution position sensors
• Fully closed‑loop control
• In‑house developed motor, driver, and algorithm
Performance Highlights
• Excellent EMI immunity
• Near‑zero thermal drift
• High scanning speed
• Compact footprint, low heat dissipation
• Long‑term operational stability
Primary Markets
Food & beverage packaging · Pharmaceutical packaging · Architectural ceramics · Decorative gifts & crafts · Electronic components · Mobile phone, laptop & tablet enclosures · Wire stripping · Film cutting · PCB barcode marking · Equipment nameplates

PRODUCT PARAMETER
| Item |
Parameter |
| Product Series |
MACF0801 Dual-Light Series |
| Scale speed |
3000mm/s (JZC software test) |
| Product Model |
MACF0801(光纤)、MACF0801(CO2)、MACF0801(UV) |
| Compatible types |
optical fiber / CO2 / UV |
| Compatible wavelength |
1064 nm / 10.6 nm / 355 nm |
| Entrance light spot |
< 6.5mm |
| beam displacement |
12.54mm |
| Follow-up error |
0.2ms |
| Repeatability |
< 30 μrad |
| Zero drift |
< 30 μrad/°C |
| Gain drift |
< 110 ppm/K |
| Drifting for more than 8 hours |
< 0.5 mrad |
| 1% of the total journey |
0.5 ms |
| 10% of the entire journey |
1.3 ms |
| Positioning speed |
9 m/s |
| Scanning angle |
±20 ° |
| Gain error |
<10 mrad |
| Zero-point error |
<10 μrad |
| Nonlinearity |
<0.9 mrad |
| Power requirements |
±15 V / 2 A |
| Digital Interface |
XY2-100 |
| Operating temperature |
25 ± 10 °C |
| weight |
1 kg |